Spesifikasi
The range of measurements of the propagation of ultrasonic vibrations, µs: 10 … 9999
The measurement resolution of the propagation time of ultrasonic vibration, µs: 0,1
The operating frequency of the ultrasonic oscillations, kHz: 50–100
The base surface sounding measurements, mm: 120
The output voltage, V: up to 600
Storage of measurement results: 128 (1000 cells)
Overall dimensions of el. unit, mm: 122×76×37
Operating temperature, °C: -20 … +40 °C
Power: 2 pcs AA batteries
Time of continuous operation, h, not less: 10
Standard: ASTM C597-16